Product Summary

Size: 48T,96T

Sensitivity: 4.03ng/L

Detection range: 7-1500ng/L

Sample type: Serum, plasma, cell culture supernates

Reactive with: Human

Product Summary

Size: 48T,96T

Sensitivity: 4.03ng/L

Detection range: 7-1500ng/L

Sample type: Serum, plasma, cell culture supernates

Reactive with: Human

Product overview

Full product name

Period Circadian Protein Homolog 1

Code

E3019Hu

Assay type

Sandwich

Size

48T,96T

Sensitivity

4.03ng/L

Detection range

7-1500ng/L

Sample type

Serum, plasma, cell culture supernates

Species

Human

Storage

2-8ºC

Assay time

1h 30m

Background

Transcriptional repressor which forms a core component of the circadian clock. The circadian clock, an internal time-keeping system, regulates various physiological processes through the generation of approximately 24 hour circadian rhythms in gene expression, which are translated into rhythms in metabolism and behavior. It is derived from the Latin roots 'circa' (about) and 'diem' (day) and acts as an important regulator of a wide array of physiological functions including metabolism, sleep, body temperature, blood pressure, endocrine, immune, cardiovascular, and renal function. Consists of two major components: the central clock, residing in the suprachiasmatic nucleus (SCN) of the brain, and the peripheral clocks that are present in nearly every tissue and organ system. Both the central and peripheral clocks can be reset by environmental cues, also known as Zeitgebers (German for 'timegivers'). The predominant Zeitgeber for the central clock is light, which is sensed by retina and signals directly to the SCN. The central clock entrains the peripheral clocks through neuronal and hormonal signals, body temperature and feeding-related cues, aligning all clocks with the external light/dark cycle. Circadian rhythms allow an organism to achieve temporal homeostasis with its environment at the molecular level by regulating gene expression to create a peak of protein expression once every 24 hours to control when a particular physiological process is most active with respect to the solar day. Transcription and translation of core clock components (CLOCK, NPAS2, ARNTL/BMAL1, ARNTL2/BMAL2, PER1, PER2, PER3, CRY1 and CRY2) plays a critical role in rhythm generation, whereas delays imposed by post-translational modifications (PTMs) are important for determining the period (tau) of the rhythms (tau refers to the period of a rhythm and is the length, in time, of one complete cycle). A diurnal rhythm is synchronized with the day/night cycle, while the ultradian and infradian rhythms have a period shorter and longer than 24 hours, respectively. Disruptions in the circadian rhythms contribute to the pathology of cardiovascular diseases, cancer, metabolic syndromes and aging. A transcription/translation feedback loop (TTFL) forms the core of the molecular circadian clock mechanism. Transcription factors, CLOCK or NPAS2 and ARNTL/BMAL1 or ARNTL2/BMAL2, form the positive limb of the feedback loop, act in the form of a heterodimer and activate the transcription of core clock genes and clock-controlled genes (involved in key metabolic processes), harboring E-box elements (5'-CACGTG-3') within their promoters. The core clock genes: PER1/2/3 and CRY1/2 which are transcriptional repressors form the negative limb of the feedback loop and interact with the CLOCK|NPAS2-ARNTL/BMAL1|ARNTL2/BMAL2 heterodimer inhibiting its activity and thereby negatively regulating their own expression. This heterodimer also activates nuclear receptors NR1D1/2 and RORA/B/G, which form a second feedback loop and which activate and repress ARNTL/BMAL1 transcription, respectively. Regulates circadian target genes expression at post-transcriptional levels, but may not be required for the repression at transcriptional level. Controls PER2 protein decay. Represses CRY2 preventing its repression on CLOCK/ARNTL target genes such as FXYD5 and SCNN1A in kidney and PPARA in liver. Besides its involvement in the maintenance of the circadian clock, has an important function in the regulation of several processes. Participates in the repression of glucocorticoid receptor NR3C1/GR-induced transcriptional activity by reducing the association of NR3C1/GR to glucocorticoid response elements (GREs) by ARNTL:CLOCK. Plays a role in the modulation of the neuroinflammatory state via the regulation of inflammatory mediators release, such as CCL2 and IL6. In spinal astrocytes, negatively regulates the MAPK14/p38 and MAPK8/JNK MAPK cascades as well as the subsequent activation of NFkappaB. Coordinately regulates the expression of multiple genes that are involved in the regulation of renal sodium reabsorption. Can act as gene expression activator in a gene and tissue specific manner, in kidney enhances WNK1 and SLC12A3 expression in collaboration with CLOCK. Modulates hair follicle cycling. Represses the CLOCK-ARNTL/BMAL1 induced transcription of BHLHE40/DEC1.

UniProt accession

MASS(Da)

136,212

GeneID

5187

Synonyms

Circadian clock protein PERIOD 1;Circadian pacemaker protein Rigui;hPER1;PER 1;PER1;Period circadian protein homolog 1

Gene names

PER1

Research area

Others

Target protein

PER1

Components

Components Quantity
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard solution 0.5ml x1
Standard diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop solution 6ml x1
Substrate solution A 6ml x1
Substrate solution B 6ml x1
Wash buffer concentrate (25x) 20ml x1
Biotinylated antibody 1ml x1

Protocol data

These standard curves of E3019Hu are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

Concentration O.D. Average Corrected
800ng/L 2.43 2.516 2.476
2.602
400ng/L 1.541 1.513 1.473
1.485
200ng/L 0.769 0.824 0.784
0.88
100ng/L 0.481 0.499 0.459
0.517
50ng/L 0.272 0.252 0.212
0.232
0ng/L 0.033 0.041 0
0.049

Precision

We measured random samples of E3019Hu within the same batch/lot to ensure the consistency of the kits' performances.

Intra/Inter-Assay Sample n Mean Standard Deviation CV%
Intra-Assay 1 18 98.3 5.9 6
Intra-Assay 2 18 217.1 11.85 5.5
Intra-Assay 3 18 477.7 17.29 3.6

Protocols

References

Customer reviews and Q&As

No reviews
No reviews
  • Size

    Code

    Price

  • 48T

    E3019Hu

    $320.00

  • 96T

    E3019Hu

    $458.00

Add to Cart

Lead time: Within two weeks

We are continuously updating our ELISA Kit catalog with advanced verified products. If you can not download the datasheet please send your request of our latest datasheet.

Newsletter

Sign up

Newsletter

Sign up