Tel:86 021 3100 7137

Publish and get free product : share with us your publications using BT LAB product and get free products.
Home > Product > ELISA Kit > Human Hla Class 2 Histocompatibility Antigen, Dp Alpha 1 Chain, HLA-DPA1 ELISA Kit

Human Hla Class 2 Histocompatibility Antigen, Dp Alpha 1 Chain, HLA-DPA1 ELISA Kit

Human Hla Class 2 Histocompatibility Antigen, Dp Alpha 1 Chain, HLA-DPA1 ELISA Kit

Product Summary

Size: 48T,96T

Sensitivity: 35.14ng/L

Detection range: 70-15000ng/L

Sample type: Serum, plasma, cell culture supernates

Reactive with: Human

Product Summary

Size: 48T,96T

Sensitivity: 35.14ng/L

Detection range: 70-15000ng/L

Sample type: Serum, plasma, cell culture supernates

Reactive with: Human

Product overview

Full product name

Hla Class 2 Histocompatibility Antigen, Dp Alpha 1 Chain

Code

E5424Hu

Assay type

Sandwich

Size

48T,96T

Sensitivity

35.14ng/L

Detection range

70-15000ng/L

Sample type

Serum, plasma, cell culture supernates

Species

Human

Storage

2-8ºC

Assay time

1h 30m

Background

Binds Peptides derived from antigens that access the endocytic route of antigen presenting cells (APC) and presents them on the cell surface for recognition by the CD4 T-cells. The Peptide binding cleft accommodates Peptides of 10-30 residues. The Peptides presented by MHC class II molecules are generated mostly by degradation of proteins that access the endocytic route, where they are processed by lysosomal proteases and other hydrolases. Exogenous antigens that have been endocytosed by the APC are thus readily available for presentation via MHC II molecules, and for this reason this antigen presentation pathway is usually referred to as exogenous. As membrane proteins on their way to degradation in lysosomes as part of their normal turn-over are also contained in the endosomal/lysosomal compartments, exogenous antigens must compete with those derived from endogenous components. Autophagy is also a source of endogenous Peptides, autophagosomes constitutively fuse with MHC class II loading compartments. In addition to APCs, other cells of the gastrointestinal tract, such as epithelial cells, express MHC class II molecules and CD74 and act as APCs, which is an unusual trait of the GI tract. To produce a MHC class II molecule that presents an antigen, three MHC class II molecules (heterodimers of an alpha and a beta chain) associate with a CD74 trimer in the ER to form a heterononamer. Soon after the entry of this complex into the endosomal/lysosomal system where antigen processing occurs, CD74 undergoes a sequential degradation by various proteases, including CTSS and CTSL, leaving a small fragment termed CLIP (class-II-associated invariant chain Peptide). The removal of CLIP is facilitated by HLA-DM via direct binding to the alpha-beta-CLIP complex so that CLIP is released. HLA-DM stabilizes MHC class II molecules until primary high affinity antigenic Peptides are bound. The MHC II molecule bound to a Peptide is then transported to the cell membrane surface. In B-cells, the interaction between HLA-DM and MHC class II molecules is regulated by HLA-DO. Primary dendritic cells (DCs) also to express HLA-DO. Lysosomal microenvironment has been implicated in the regulation of antigen loading into MHC II molecules, increased acidification produces increased proteolysis and efficient Peptide loading.

UniProt accession

MASS(Da)

29,381

GeneID

3113

Synonyms

DP(W3;DP(W4;HLA class II histocompatibility antigen, DP alpha 1 chain;HLA DP;HLA-DPA1;HLA-SB alpha chain;MHC class II DP3-alpha;MHC class II DPA1;PHLA DPA1;

Gene names

HLA-DPA1

Research area

Immunology

Target protein

HLA-DPA1

Components

Components Quantity
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard solution 0.5ml x1
Standard diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop solution 6ml x1
Substrate solution A 6ml x1
Substrate solution B 6ml x1
Wash buffer concentrate (25x) 20ml x1
Biotinylated antibody 1ml x1

Protocol data

These standard curves of E5424Hu are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

Concentration O.D. Average Corrected
8000ng/L 1.96 1.932 1.878
1.904
4000ng/L 0.898 0.978 0.924
1.058
2000ng/L 0.486 0.518 0.464
0.55
1000ng/L 0.196 0.219 0.165
0.241
500ng/L 0.075 0.108 0.054
0.14
0ng/L 0.047 0.054 0
0.061

Precision

We measured random samples of E5424Hu within the same batch/lot to ensure the consistency of the kits' performances.

Intra/Inter-Assay Sample n Mean Standard Deviation CV%
Intra-Assay 1 18 4534.6 207.27 4.6
Intra-Assay 2 18 6302.9 154.72 2.5
Intra-Assay 3 18 2269.4 111.84 4.9

Protocols

References

Customer reviews and Q&As

No reviews
No reviews
  • Size

    Code

    Price

  • 48T

    E5424Hu

    $320.00

  • 96T

    E5424Hu

    $458.00

Add to Cart

Lead time: Within two weeks

We are continuously updating our ELISA Kit catalog with advanced verified products. If you can not download the datasheet please send your request of our latest datasheet.

Newsletter

Sign up

Newsletter

Sign up