Product overview
Full product name
Size
Sensitivity
Detection range
Sample type
Code
Assay type
Species
Storage
Assay time
Research area
Target protein
Components
| Components | Quantity |
|---|---|
| Pre-coated Plate | 8 wells * 12 detachable strips |
| Standard, lyophilized | 2 vials |
| Standard/Sample Diluent | 6ml ×1 vial |
| Biotinylated Antigen, lyophilized | 1 vial |
| Avidin-HRP Concentrate | 100μl × 1 vial |
| Biotinylated Antigen Diluent | 6ml × 1 vials |
| Avidin HRP Diluent | 5.9ml × 1 vials |
| Substrate Solution A | 6ml ×1 vial |
| Substrate Solution B | 6ml ×1 vial |
| Stop Solution | 6ml ×1 vial |
| Wash Buffer Concentrate (25x) | 20ml × 1 vial |
Protocol data
These standard curves of EA0004FI are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
| Concentration | O.D. | Average | Corrected |
| 0ng/ml | 2.11 | 2.056 | 2.008 |
| 2.002 | |||
| 0.8ng/ml | 1.526 | 1.493 | 1.445 |
| 1.46 | |||
| 1.6ng/ml | 1.253 | 1.282 | 1.234 |
| 1.312 | |||
| 3.2ng/ml | 0.723 | 0.765 | 0.717 |
| 0.807 | |||
| 6.4ng/ml | 0.413 | 0.402 | 0.354 |
| 0.391 | |||
| 12.8ng/ml | 0.184 | 0.173 | 0.125 |
| 0.162 |
Precision
We measured random samples of EA0004FI within the same batch/lot to ensure the consistency of the kits' performances.
| Intra/Inter-Assay | Sample | n | Mean | Standard Deviation | CV% |
| Intra-assay | 1 | 18 | 5 | 0.3 | 5.9 |
| Intra-assay | 2 | 18 | 2.6 | 0.2 | 7.5 |
| Intra-assay | 3 | 18 | 1.5 | 0.1 | 6.4 |